JLG X20JP - X600AJ Service Manual User Manual
Page 283
Advertising
SECTION 6 - JLG CONTROL SYSTEM
3121623
– JLG Lift –
6-67
Add weight of 200 kg (CE) / 440 Lb (ANSI) in the basket.
200KG OR 440LB ARE THE CORRECT WEIGHT FOR THE CALIBRA-
TION
Wait for about 5 seconds.
Press button 2 to SET 200KG.
Press 3 times button 9 to Esc to escape.
NOTE: Using the password "Level 3" 5726 to read the values
only
LSS VALIDATION
1. Stabilize the machine.
2. Press button 6 "SERVICE“.
3. Press button 1 INP OUT.
4. Press button 2 “SUCC” until shown “LOAD”.
Check that the value if is in reference to the weight
on the basket.
If the values shown is almost greater than 10 kg, repeat
the procedure.