SECTION 6 - JLG CONTROL SYSTEM

3121623

– JLG Lift –

6-67

Add weight of 200 kg (CE) / 440 Lb (ANSI) in the basket.

200KG OR 440LB ARE THE CORRECT WEIGHT FOR THE CALIBRA-
TION

Wait for about 5 seconds.

Press button 2 to SET 200KG.

Press 3 times button 9 to Esc to escape.

NOTE: Using the password "Level 3" 5726 to read the values

only

LSS VALIDATION

1. Stabilize the machine.

2. Press button 6 "SERVICE“.

3. Press button 1 INP OUT.

4. Press button 2 “SUCC” until shown “LOAD”.

Check that the value if is in reference to the weight
on the basket.

If the values shown is almost greater than 10 kg, repeat
the procedure.