RAMHINO LITHIUM SETTING PROCEDURES

Once the Rahmino tool is connected and initialized, open
the lithium battery system folder.

Press Z + P at the same time. Password is h1n0w4. The
settings screen below will appear:

ENABLE CONFIGURATION: Button for the lithium pack
contactor opening. Opening the contactor the state
“parametrization” become ON.

Figure 6-106.

DISABLE CONFIGURATION: Button for the lithium pack
contactor closing.

Figure 6-107.

BATTERY SYNC: Flag to restart the can bus communica-
tion if interrupted.

Figure 6-108.

SOC RESET PROCEDURE:

SOC indicates the charge percentage of the pack consid-
ering the total pack capacity.
BE CAREFUL: pressing that button the process of SOC
reset is automatically starting. The current status of pack
charge is becoming the 100% of the pack capacity.

Figure 6-109.

 

 