4 rack mounting – Behringer Eurolight 24-Channel DMX Lighting Console LC2412 User Manual

Page 21

Advertising
background image

21

EUROLIGHT LC2412 User Manual

9.3.2 Sub D connections (Analog Control)
The following table shows the cable layout of the individual contacts of the sub D

connection for analog dimmer control.

Pin No.

Cons. channel

Pin 1

Channel 1

Pin 2

Channel 2

Pin 3

Channel 3

Pin 4

Channel 4

Pin 5

Channel 5

Pin 6

Channel 6

Pin 7

Channel 7

Pin 8

Channel 8

Pin 9

Channel 9

Pin 10

Channel 10

Pin 11

Channel 11

Pin 12

Channel 12

Pin 13

Special 1

Pin 14

Special 2

Pin 15

Ground

Table. 9.1: Cable layout of the sub D connection

9.3.3 MIDI connection
Coonect to other MIDI equipment or another EUROLIGHT LC2412 by using

common MIDI cables. The cables should never be longer than 15 m (45 ft).

9.3.4 Audio connections
To control the EUROLIGHT LC2412 via an audio signal, please use a mono jack

connector with standard configuration.

strain relief clamp

sleeve

tip

sleeve

(ground/shield)

Unbalanced ¼" TS connector

tip

(signal)

Fig. 9.2: 1/4" TS connector for audio signals

9.3.5 Footswitch
You can use a footswitch to trigger chase steps. This way, both of your hands

remain free, letting you control additional settings of your LC2412.

strain relief clamp
sleeve

tip

sleeve

pole 1/ground

tip

pole 2

The footswitch connects both poles momentarily

¼" TS footswitch connector

Fig. 9.3: Footswitch connector

As long as a footswitch is kept pressed, the connection of both contacts is closed.

Therefore, a footswitch does not act as a switch.

9.4 Rack mounting

Your EUROLIGHT LC2412 is factory-equipped with rack-mounting brackets.

You can screw these on to the side of your LC2412 on a per-need basis.

Always make sure that your LC2412 is provided with sufficient
ventilation to avoid overheating of the unit!

Advertising