5 network connection (rj45), 6 serial com interface (rs232) – ADS-TEC IPC1100/1200 User Manual

Page 22

Advertising
background image

Industrial PCs IPC1100/1200

22

© ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen

6.5

N

ETWORK CONNECTION

(RJ45)

If the drivers required for functioning are installed on the device, the control system may

be integrated in an Ethernet network supporting the 10/100 Mbit standard by using the
Ethernet 10/100BaseT network connector. Specifications of this network topology must be
observed in this case. You can install the drivers required for functioning from the enclosed

service CD, should they not be installed on the device.

PIN NUMBER

SIGNAL NAME

1

TX +

2

TX -

3

RX +

4

NC

5

NC

6

RX -

7

NC

8

NC

Pos : 31 /D atent ec hni k/Schnitts tell en/Seriell e Schnitts tell e C OM RS232/Serielle Sc hnitts tell e C OM (RS232) f ür OPC / I PC / C PC / PLC / OTC / ITC / VMT / M SA- Serie @ 1\ mod_1249303286408_681.doc @ 6105 @

6.6

S

ERIAL

COM

INTERFACE

(RS232)

The serial interface is used for digital and for analogue data transmission as well. The RS

232 interface can be connected by using a commercially available 9-pin SUB-D cable.

PIN NUMBER

SIGNAL NAME

1

DCD

2

RxD

3

TxD

4

DTR

5

GND

6

DSR

7

RTS

8

CTS

9

RI

Note:
This interface is not electrically isolated.

Pos : 32 /D atent ec hni k/Lauf wer ke/Exter ne Lauf werke/ Ext er ne Lauf wer ke für OPC 5112 / 5115 / 5117 / I PC 1100 / CPC / PLC / OTC / ITC / VMT-Serie @ 0\ mod_1158926656205_681. doc @ 880 @

Advertising