38

DR66 & DR128 Installer User Guide

Version 1 – Resetting the Password

(Not available in Version 2)

The Front Panel Setup Menu can be password protected to prevent unauthorised tampering. If
you lose or forget this password it can be reset using the procedure below.

First remove power from the DR and then remove the top cover. Locate and fit the password reset
link on the CPU circuit board. The link is marked JP2 on the circuit board. Then turn on the DR
unit again. If the unit detects that the link is shorted when it powers up, the password will be reset
to ‘????’ and the security turned OFF. Turn off the power again and remove the link before fitting
the top cover.

Getting Information on Version 1.83

Allen & Heath continues to support V1.83. This software can be downloaded from the Allen &
Heath Web site. The full release history and instructions are provided on the site. The older user
guides are available. However, this appendix provides sufficient V1.83 information for the
experienced installer using this user guide. Contact Allen & Heath tech support for information on
the following if required:

Publication AP3138 DR66 User Guide (Version 1 software)

Publication AP2973 DR128 User Guide (Version 1 software)

Publication AP3168 DR66 SysNet Option Fitting Instructions

Publication AP3165 DR128 SysNet Option Fitting Instructions