General maintenance, Troubleshooting – Altman Lighting Phoenix LED Profile Spot User Manual

Page 12

Advertising
background image


Altman Lighting, Inc.

57 Alexander Street., Yonkers, NY 10701

1-800-4-ALTMAN

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. COPYRIGHT 2012© ALTMAN LIGHTING, INC/ ALL RIGHTS RESERVED

1/24/14 rev:C

12

General Maintenance

In order to insure longevity of your fixture, regular cleaning is necessary. The lens and fan
must be cleaned periodically to allow proper function of the fixture. Do not use alcohol or any
other solvent with chemicals to clean the lens. When cleaning your lens, use a clean soft lint
free cloth with damp with water. Do not use any hard materials to wipe the lens. Maintenance
and cleaning of your fixture depends on the frequency of use and the environmental conditions
your fixture is kept in. Make sure the fan is kept free of lint and dust to allow proper air flow.
To avoid damage to the shell of your fixture do not use alcohol or other organic solvents.

Troubleshooting

Problem

Action

Unable to start / Power

Check the power line connection between the fixture and electric source.

Check DMX Address.

Check the fan and make sure there is no dust or debris is blocking the

Check the Lifetime of the LEDs, make sure the lenses are clean.

Data Signal Problems

Check Data lines and make sure all cables are in good condition.

Check the termination points.

Intensity of the beam is dim

Fixture Power Intermittence

Imperfections in the beam

Make sure the lens is clean and free of cracks

Beam distortion

Make sure the lens is clean and free of cracks