Method 2: Hardware

When set with jumpers, the Activator ID is a binary number

represented by jumpers. A

1 is represented by a jumper on the

header and a

0 is represented by an absence of a jumper (Table 2).

Once an Activator ID is set by jumpers, it can

not be reset with serial

commands. In order for serial commands to take effect, the jumpers

must be removed, the unit must powered down and then rebooted.

However, even with the jumpers removed the Activator will maintain

the ID that had been set with jumpers until reprogrammed with the

serial command.

NOTE

Before the Activator ID is set with jumpers, the default ID is 127,

although there are no jumpers on the headers.

ID#

Jumpers

JP19 JP12

ID#

Jumpers

JP19 JP12

3

0 0 0 0 0 0 1 1

70

0 1 0 0 0 1 1 0

13

0 0 0 0 1 1 0 1

72

0 1 0 0 1 0 0 0

14

0 0 0 0 1 1 1 0

75

0 1 0 0 1 0 1 1

21

0 0 0 1 0 1 0 1

80

0 1 0 1 0 0 0 0

22

0 0 0 1 0 1 1 0

83

0 1 0 1 0 0 1 1

24

0 0 0 1 1 0 0 0

93

0 1 0 1 1 1 0 1

27

0 0 0 1 1 0 1 1

94

0 1 0 1 1 1 1 0

33

0 0 1 0 0 0 0 1

100

0 1 1 0 0 1 0 0

34

0 0 1 0 0 0 1 0

103

0 1 1 0 0 1 1 1

44

0 0 1 0 1 1 0 0

105

0 1 1 0 1 0 0 1

47

0 0 1 0 1 1 1 1

106

0 1 1 0 1 0 1 0

52

0 0 1 1 0 1 0 0

113

0 1 1 1 0 0 0 1

55

0 0 1 1 0 1 1 1

114

0 1 1 1 0 0 1 0

57

0 0 1 1 1 0 1 0

124

0 1 1 1 1 1 0 0

58

0 1 0 0 0 1 0 1

127

0 1 1 1 1 1 1 1

69

0 1 0 0 0 1 1 0

Table 2 Activator IDs and their jumper positions

To set the Activator ID with jumpers

1: Power down the Activator and disconnect the wake-up antenna.