Configuring the Activator

The Activator can be configured with its own user-defined location ID

via serial port (using a PC or terminal communications device) or

manually via jumpers. The unit installs easily and offers flexible

coverage for perimeter doors, interior zones, vehicle lanes and other

control points throughout the facility.

The following items are necessary for the successful configuration of

the Activator:

A computer with a terminal program and a free communications port

A standard one-to-one computer modem RS-232 cable with a DB9 male

connector (Receiver end) and a suitable connector for the PC/terminal

end

IMPORTANT! Do not

use a null-modem cable or null-modem adapter

.

Connecting Power

Activators come with a 24V DC, 1 Amp power transformer that plugs

into a standard 110V AC outlet. The transformer is pre-wired into the

terminal block at the factory. IF uninterruptible power is an issue, a

backup battery or UPS can be used.

To connect power to the Activator

1: Connect the antenna to the Activator in order for the antenna

auto-tune feature to function when power is applied. Auto-tune

takes place each time power is cycled.

2: Plug the power terminal block into the back of the Activator

(Figure 3).

TX OUTPUT

PWR

TX RX

TM

TM

From

Transmit Antenna

BNC

Connector

Front Panel

GND +24VDC

POWER

RS-232

DATA

TX CNTL

-

+

Back Panel

Power

Terminal Block

To 24V DC

Source

Figure 3 Connecting power to the Activator

3: Plug the AC adapter into a 110-volt outlet.