Activation field size – Axcess Activator Installation Guide User Manual

Page 17

Advertising
background image

Activator Installation Manual

© 202, AXCESS Inc.

750.001.006 R0003

17

Activation Field Size

The Tag activation area can be controlled by adjusting the size of

the activation field. For example, you may want to shrink the

activation field to concentrate the field near a doorway,

preventing activation of tags further up the hall.

NOTE

Each Activator is shipped from the factory with its activation

control adjusted to its highest level.

Adjusting the Field
The size of the activation field is controlled by the TX CNTL screw

on the back of the Activator (Figure 10). The screw can turn in

one direction 30 times. After it has been turned 30 times in one

direction, it will make a soft clicking sound. The clicks indicate

that continuing in this direction will no longer have an effect on

the field’s size. When you hear this sound, the wake-up field has

been adjusted to one extreme or the other.

TX CNTL

-

+

Figure 10 Adjust the size of the activation field

To Reduce the Activation Field

Rotate the TX CTRL screw

clockwise with the supplied tuning

wand. Constantly check the field with an LED Test Tag to ensure

that the field is the size that you want.

TIP

The system will stop functioning if the activation control is turned

down too low. To fix this, turn the screw counter-clockwise until it clicks.

Then slowly reduce the field by tuning the TX CNTL screw clockwise

while checking its size.

To Enlarge the Activation Field

Rotate the TX CTRL screw

counter-clockwise with the supplied

tuning wand. When it clicks, it has been tuned up as high as

possible.

After Adjusting the Field

Cycle the power on the Activator after the field has been adjusted.

Advertising