I. INSTALLATION INSTRUCTIONS

1. RECEIVING:

2. CLEARANCES:

Read the notice on the outside carton regarding damage in transit. Damage discovered after

opening the crate(s) / carton(s) is “CONCEALED DAMAGE” and the carrier must be notified immediately to

send an inspector and also furnish the forms for the consignee's claim against the carrier.

When oven arrives, it should consist of : A crate, or carton, containing your new oven, a carton,

containing 4 legs with mounting hardware, and a strapped skid, containing baking decks.

Installation must conform with local codes and/or with the latest edition of the ANS Z-233.1 National

Fuel Gas Code in USA/ CAN/CGA-B 149.1 or 2 Installation Code in Canada.

This appliance must be installed by a competent person. In the U.K., Corgi registered Installers (including

the regions of British Gas) undertake to work to safe and satisfactory standards. This appliance must be

installed in accordance with the current Gas Safety (Installation and Use) Regulations and the relevant

Building Regulations / IEE Regulations. Detailed recommendations are contained in the British Standard

Codes Of Practice BS 6172, BS 5440:Part 2 and BS 6891.

Place the oven and parts as close as possible to the area of final installation before un-crating.

Minimum Clearance From

Combustible Construction

Non-Combustible Construction

Left Side

3” (76 mm)

0

Right Side

1” (25 mm)

0

Rear

3” (76 mm)

2” (51 mm)

Front and FlueArea - Enclose only with non-combustible materials.

A. Provisions must be made for easy access to the louvered service panel on the left side of the unit.

A removable panel at least 16” x 31” (406 x 787 mm) in line with the service panel to facilitate a service

man to work will be satisfactory. See installation sketch “A”.

B. Reference to back panels deleted. No longer necessary.

C. Easy accessibility through the front of the oven to the main burner, oven controls and flue slide push /

pull knobs must be provided. See installation sketch “B”.

"

Sketch “A”

NEMA 5-15P

115 VAC, 15 AMP

16"

(406mm)

60°

LEFT SIDE VIEW

3/4 NPT GAS INLETS

Lintel Plate

Louvered Service Panel