Barranca Diamond MK-100 TILE SAW User Manual

Page 19

Advertising
background image

19

CONNECTING WATER PUMP

(A)

Connect the Cooling

Transfer Tube to the

inlet connection of the

Blade Guard.

(B)

Connect the Water Pump

power cord to the connection

found on the back of the motor.

To prevent the possibility of electrical shock, the MK-100 MUST be de-energized

when connecting the Water Pump.

To prevent the possibility of electrical shock, use only MK Diamond qualified

replacement parts.

WARNING

To prevent pump damage, the Water Pump must be disconnected from its power

supply if cutting with a Dry Blade.

WATER PUMP SETUP FOR OPERATION

The Water Pump can be setup for operation in two ways, external water source or Re-circulation.

EXTERNAL WATER SOURCE

This is the preferred method of cooling.

(A)

Remove the Drain Plug.

Place empty container under

hole for water drainage.

(B)

Place the Water Pump in an

external container and fill until

water completely covers the

Water Pump suction.

NOTE:

MK-100 TILE SAW

SETUP

Advertising