Specifications – Det-Tronics GP16XX Standard Gas Panel User Manual

Page 10

Advertising
background image

1.1

95-8671

8

speciFications

OPERaTING VOLTaGE—

120-220 Vac input, 24 Vdc @ 10A output.

COMPONENTS—

EQ3001 EQP Controller

EQ3710 AIM Analog Input Module (Optional)

EQ2220 GFM Ground Fault Monitor (Included)

5.7” Human Machine Interface (HMI) - Included

24 Vdc, 10A Power Supply (Included).

TEMPERaTuRE RaNGE—

Operating: +32°F to +122°F (0°C to +50°C)

Storage: –4°F to +140°F (–20°C to +60°C).

HuMIDITY RaNGE (Instrument only)—

10 to 95% RH, non-condensing.

WEIGHT—

26.5 lb (12.0 kg) to 28.5 lb (13.0 kg), depending on

configuration.

DIMENSIONS—

24 In. (60.9 mm) x 24 In. (60.9 mm) x 6.4 In. (16.2 mm).

See Figure 1.

ENCLOSuRE—

Finish: ANSI 61 Gray

Door: 16 Gauge Steel

Body: 18 Gauge Steel.

CERTIFICaTION—

Certification of the system's components:

EQ3001 Controller
FM/CSA:

Class I, Div. 2 Groups A, B, C, D (T4)

ATEX/CE:

FM

APPROVED

®

II 3 G

Ex

nC

IIC

EN

60079-29-1

IECEx:

Ex nC IIC

EQ3710 AIM
FM/CSA:

Class I, Div. 2 Groups B, C, D (T4)

Class I, Zone 2, Group IIC (T4)

Gas Performance certified

ATEX/CE:

FM

APPROVED

®

II 3 G

Ex nA nL nC IIC

EN

60079-29-1

IECEx:

Ex nA nL nC IIC

EQ2220 GFM
FM/CSA:

Class I, Div. 2 Groups A, B, C, D (T4)

ATEX/CE:

FM

APPROVED

®

II 3 G

Ex nC IIC

IECEx:

Ex

nC

IIC

HMI
UL:

Class I, Div. 2 Groups A, B, C, D (T4)

ATEX/CE:

Ex nA nC IIC

System performance compliance in ordinary locations to:
ANSI/ISA:

12.13.01-2000, 92.0.01-1998

FM:

6310, 6320

CSA:

22.2, No. 152

ATEX/CE:

EN 60079-29-1

NOTE: When a non-certified stand alone detector is

used with the GP16XX, the output from that device is not

a certified function (when connected to AIM Module).

FM

APPROVED

®

Advertising