Det-Tronics UD20 FlexVu Explosion-Proof Universal Display Unit User Manual

Page 11

Advertising
background image

3.1

95-8620

9

cerTiFicaTionS—

FM:

Class I, Div. 1, Groups B, C & D;

Class I, Div. 2, Groups B, C & D (T4);

Class I, Zone 1/2 AEx d IIC T6;

Class II/III, Div. 1/2, Groups E, F & G.

Tamb –20°C to +70°C

NEMA/Type 4X, IP66

Conduit seal not required.

Performance verified in accordance with:

ANSI/ISA-92.0.01

ANSI/ISA-92.02.01

FM 6341 (Draft)

ANSI/ISA-12.13.01

ANSI/ISA-12.13.04/FM 6325

FM 6310/6320

CSA:

CSA 08 2162793.

Class I, Div. 1, Groups B, C & D;

Class I, Div. 2, Groups B, C & D (T4);

Class II/III, Div. 1/2, Groups E, F & G.

(Tamb = –20°C to +70°C)

Type 4X, IP66

Conduit seal not required.

ATEX:

0539

FM

APPROVED

II 2 G

Ex d IIC T6 Gb

Tamb –20°C to +70°C

FM08ATEX0044X

IP66

Performance verified in accordance with:

EN 61779-1/-4 and EN 50241-1/-2.

IECEx:

Ex d IIC T6 Gb

Tamb –20°C to +70°C

IECEx FMG 08.0010X

IP66

Performance verified in accordance with:

IEC 61779-1, -4.

INMETRO

CEPEL 12.2128

Ex d IIC T6 Gb IP66

T6 (Tamb –20°C to +70°C)

All cable entry devices shall be Brazil certified in the

type of explosion protection, flameproof enclosure ‘d’,

suitable for the conditions of use and correctly installed,

with an ingress protection rating of IP66.

A screw or cover lock is provided for a secondary

means of fastening the cover.

FM

APPROVED

®

FM

APPROVED

®

Figure 7—Dimensions of Model STb Termination box

in inches (centimeters)

3.77

(9.6)

1.28

(3.3)

3.46

(8.8)

4.7

(11.9)

2.7

(6.9)

5.2

(13.2)

5.86

(14.9)

C2281

FM

APPROVED

Advertising