INSTRUCTIONS

FlexVu

®

Explosion-Proof

Universal Display Unit

Model UD20

Important

Be sure to read and understand the entire
instruction manual before installing or operating
the gas detection system. The Model UD20 is to
be used with the GT3000 to provide early warning
of the presence of a toxic gas mixture. Proper
device installation, operation, and maintenance is
required to ensure safe and effective operation. If
this equipment is used in a manner not specified in
this manual, safety protection may be impaired.

ApplicAtion

The FlexVu

®

Model UD20 Universal Display Unit is

designed to be used with the GT3000 Toxic Gas

Detector.

It is recommended for applications where a 2-wire loop

powered gas detector is required. The output is a 4-20

mA signal with HART, corresponding to the output of

the GT3000 detector.

Gas concentrations are displayed on an alpha-numeric

display in ppm (% for O

2

). The display unit reads the

linear 4-20 mA DC output signal from the GT3000 that

corresponds to the detected gas concentration. The

UD20 automatically detects the gas type and operating

range of the sensor to which it is connected via the

HART signal.

All electronics are enclosed in an explosion-proof

aluminum or stainless steel housing. The display unit

is used with a single GT3000, which may be either

directly coupled to the display unit, or remotely located

using a sensor termination box. The UD20 features

non-intrusive calibration, which can be performed by

using a handheld magnet to activate internal magnetic

switches on the faceplate. Calibration can also be

performed by activating the GT3000’s internal magnetic

reed switch with a magnet.

Description

The UD20 provides display and control capabilities for the

GT3000, and utilizes the following I/O:

Signal Inputs:

4-20 mA loop with HART,

from the GT3000

User Inputs:

Magnetic switches (4),

on the display panel

Visible Outputs: LCD display

Signal Outputs:

4-20 mA loop with HART,

from the GT3000

3.1

©