Divar | Installation Manual | Hardware setup

EN | 4-3

Monitor connections

Connect the unit to the monitors using 75-ohm video coaxial cables with BNC
connectors. The unit provides a 1Vpp CVBS signal.

If the monitor has a loop-through connection and you are not using the loop-
through output, then select the 75-ohm impedance setting on the monitor. If the
monitor's loop-through output is connected to an additional device, the device's
termination is set to 75 ohms and the monitor's termination is set to high
impedance. (Note that this is not necessary on devices with automatic
termination.)

Specifications

Output signal:

Composite video 1Vpp, 75 Ohm, Sync. 0.3Vpp ±10%

Resolution:

720 x 576 PAL, 720 X 484 NTSC

Connector type:

BNC

Console port connection

The serial RS232 console port connector is used to connect a PC to the unit for
configuration or service purposes. Use a null-modem cable to connect the serial
port of the PC to the unit. The Baud rate can be selected in the menu system.

The serial RS232 console port connector is also used to connect Bosch D9000
series control panels via an interface unit for Divar alarm activation. Alarm
input mapping can be set up in the menu system.

Specification

Connector type:

9-pole D-type male connector

Maximum input voltage:

±25V

Communicaton protocol:

Output signals according EIA/TIA-232-F

RS232 console port socket

Signal Name:

Pin no.

Description

DCD_in

1

Carrier detection signal (not used).

RX

2

RS232 receive signal

TX

3

RS232 transmit signal

N/C

4

No Connection

System Ground

5

System Ground

N/C

6

No Connection

RTS

7

RS232 request to send signal

CTS

8

RS232 clear to send signal

N/C

9

No Connection

5

1

6

9

Panel view