Bosch Divar -Digital Versatile Recorder User Manual

Page 50

Advertising
background image

Bosch Security Systems

Divar | Installation Manual | Menu system

EN | 5-8

Adjust contrast

Select a camera in the menu or press a camera key on the unit. The
selected camera image appears.

Vary the manual gain value between -100 and +100 to adjust the
contrast.

To set the default value (0), press the F1 key.

>>> Camera controllable

A check mark under a camera number indicates that it can be
controlled remotely by the Control Center application.

Press a camera key on the unit to make a camera controllable or
not.

By default all cameras are controllable.

>>> Bilinx cameras

Only shown if your Divar is a Divar Bilinx.

A check mark under a camera number indicates that Bilinx control
is enabled.

Press a camera key on the unit to enabled or disable Bilinx control
for that camera.

By default all cameras are enabled.

If Bilinx cameras are looped-through to multiple Divars, only
one Divar is allowed to have Bilinx enabled!

>> SEQUENCES
The sequence in which cameras are displayed on monitor A and monitor B is set
in the full screen list menu.

Set the length of time each image remains on the screen by filling in the
dwell time value for each monitor.

Dwell time can vary from 1 to 60 seconds. The default value is 5 seconds.

>>> List Full screen monitor A

The sequence list shows the order in which the camera images are
displayed in full screen mode (Control Center version 1 only).

Use the arrow keys to select a position in the list. Press a camera key
on the unit to enter a camera number in the list.

Press F2 to clear the rest of the list.

Press F1 to restore all defaults. Connected cameras are then listed in
ascending order.

>>> List Full screen monitor B

The sequence list shows the order in which the camera images are
displayed in full screen mode (Control Center version 1 only).

Use the arrow keys to select a position in the list. Press a camera key
on the unit to enter a camera number in the list.

Press F2 to clear the rest of the list.

Press F1 to restore all defaults. Connected cameras are then listed in
ascending order.

>> CONFIGURE MONITORS

To view camera names, and time and date on a monitor set these items to
On

.

Set Motion Display to On to draw attention to any motion that occurs in
the designated zones.

Select the position for the text (top or bottom and fine position +11/-11).
Select text intensity. Select the border intensity of the cameos from four
values.

To automatically close the menu when an alarm or event occurs, set the
Exit Menu on Alarms

item to Yes.

The menu is closed after five minutes if you set the Menu Time-out to
On

.