External i/o connection – Bosch Divar -Digital Versatile Recorder User Manual

Page 39

Advertising
background image

Bosch Security Systems

Divar | Installation Manual | Hardware setup

EN | 4-7

External I/O connection

Alarm inputs and outputs are supplied via a 25-pole D-type socket. The screw
terminal input/output connection board supplied with the unit simplifies all
alarm connections to the unit.

Connecting the Inputs

Each (alarm) input line can be switched by a relay contact from devices such as
pressure pads, passive infra-red detectors, smoke detectors and similar devices.
Wire them as either N/O or N/C. You can configure the alarm inputs as N/O or
N/C in the menu system. The default is N/O.

Connecting the Alarm Outputs

The four alarm output relays respond to input alarms and triggers. You can
configure the alarm outputs as N/O or N/C in the menu system. The relays are
active for the duration of the driving event. Connect the application to the alarm
output relays (resistive loads only). Do not exceed 30 Vac, 40Vdc, 500 mA
(continuous) or 10VA on an alarm output relay's contacts. The contacts must not
be used at AC line voltages.

Specifications

Alarm input impedence:

Internal pull-up 10K to +5V

Input voltage range:

-0.3V min to 30V max

Input voltage treshold:

Low voltage 0.8V max

High voltage 2.4V min

Switching current (resistive): 500mA max

Carrying power:

10VA max

Switching voltage (resistive): 30 Vac / 40 Vdc max

External I/O - 25-pole D-type socket

1A
1B
2A
2B

R
E
L
A
Y

3A
3B
4A
4B

GND

1
2

GND

9

10

3
4

GND

11
12

5
6

GND

13
14

7
8

15
16

IN

IN

IN

IN

13

1

14

25

Panel view

Signal name:

Pin no.

Description

Alarm_in_1

1

Alarm input 1

Alarm_in_2

2

Alarm input 2

Alarm_in_3

3

Alarm input 3

Alarm_in_4

4

Alarm input 4

Alarm_in_5

5

Alarm input 5

Advertising