Control port

The control port is a bi-phase port for connecting the control units of
controllable cameras. Five bi-phase outputs are provided for dome camera and
pan, tilt and zoom control. The screw terminal connection board supplied with
the unit simplifies all bi-phase connections to the unit.

Specifications

Output impedence:

128 Ohm

Overvoltage protection:

±30V max.

Differential voltage amplitude:1V min, 2V max. with a characteristic load of 220 Ohms

connected across the differential output

Cable length:

1.5 Kilometers max.

Recommended cable:

Belden 8760

Number of loads per output: 4 max.

Control port - 15-pole D-type socket

+

-

SHIELD

CTRL 1

SHIELD

+

-

SHIELD

CTRL 2

+

-

SHIELD

CTRL 3

+

-

SHIELD

CTRL 4

+

-

SHIELD

CTRL 5

8

1

9

15

Panel view

Signal name:

Pin no.

Description

Code 1 -

1

Bi-phase control ch. 1 (minus)

Code 1 +

2

Bi-phase control ch. 1 (plus)

Shield

3

System ground/cable shield.

Code 2 -

4

Bi-phase control ch. 2 (minus)

Code 2 +

5

Bi-phase control ch. 2 (plus)

Shield

6

System ground/cable shield.

Code 3 -

7

Bi-phase control ch. 3 (minus)

Code 3 +

8

Bi-phase control ch. 3 (plus)

Shield

9

System ground/cable shield.

Code 4 -

10

Bi-phase control ch. 4 (minus)

Code 4 +

11

Bi-phase control ch. 4 (plus)

Shield

12

System ground/cable shield.

Code 5 -

13

Bi-phase control ch. 5 (minus)

Code 5 +

14

Bi-phase control ch. 5 (plus)

Shield

15

System ground/cable shield.