Auxiliary power supply(j12), Auxiliary power supply (optional) – ElmoMC Gold Line Digital Servo Drives-Gold DC Bell User Manual

Page 28

Advertising
background image

Gold DC Bell Installation Guide

MAN-G-DCBELIG-EC (Ver. 1.200)

||Main and Auxiliary Power|

www.elmomc.com

28

Table of Contents

6.3.3.

Auxiliary Power Supply(J12)

Pin(J12)

Signal

Function

Cable

1

VL+

Auxiliary Supply Input

DC Power

2

PR

Auxiliary Supply Return

DC Power

2-Pin Phoenix 3.81 mm Pitch

2-Pin Phoenix Plug-in

Connector

Table 5: Aux. Power Connector – Pin Assignments

Caution: Power from the Gold DC Bell to the motor must come from the Main
Supply and not from the Auxiliary Supply.

The backup functionality can be used for storing control parameters in case of power-outs,
providing maximum flexibility and backup capability when needed.
Connect the VL+ and PR terminal to the Auxiliary Connector.

To connect the auxiliary supply:
1.

The source of the Auxiliary Supply must be isolated.

2.

For safety reasons, connect the return (common) of the auxiliary supply source to the
closest ground near the auxiliary supply source

3.

Connect the cable shield to the closest ground near the auxiliary supply source

4.

Before applying power, first verify the polarity of the connection.

Advertising