Violin Installation Guide Installation

MAN-VIOIG (Ver. 2.3)

3-6

Pin #/
Short Form


Function


Remarks

1
LMRET

Latch mode return Return for Latch mode (LM)

2
LM

Latch mode

Latch mode input

3
EN+

Enable (+)

Positive voltage input of the "Amplifier Enable”
function. To enable operation of the amplifier,
the opto must be switched on by applying
voltage between this pin (+) and pin J2/4 (-).
The opto is isolated from the amplifier. See

Figure 2-1

.

Minimum “ON” voltage: 3 V , current

consumption 0.6 mA.

Maximum “ON” voltage: 15 V , current

consumption 5.4 mA.

4
EN-

Enable (-)

Negative voltage input of the "Amplifier
Enable” function. Opto isolated from the
amplifier. For details, see pin J2/3.

5
SORET

Status output
return

Status Outputs Common for AOK, SO1, SO2,
SO3.
Isolated from the circuit common. For details,
see

Figure 2-1

.

6
SORET

Status output
return

Status Outputs Common for AOK, SO1, SO2,
SO3.
Isolated from the circuit common. For details,
see

Figure 2-1

.

7
AOK

Amplifier OK

“Amplifier OK” indication output pin. When the
amplifier is at normal operating conditions this
output is in “active Low “ state. When a failure
occurs this output is changed to “open” state.
Opto isolated, open collector NPN type. See

Figure 2-1

.

Maximum voltage = 30 V
Maximum current = 8 mA.
“On” voltage: V

OUT(On)

< 0.8 V

8
SO1

Status output 1

Status indication output 1. Specification as in pin
J2/7.

9
SO2

Status output 2

Status indication output 2. Specification as in pin
J2/7.

10
SO3

Status output 3

Status indication output 3. Specification as in pin
J2/7.

Table 3-5: Connector J2