Model number nomenclature – Bryant 574B User Manual

Page 2

Advertising
background image

—2—

Corporate thermostats

include the Time Guard® II anti-short

cycle protection circuitry. If a non-corporate thermostat without
anti-short cycle protection is used the Time Guard II field in-
stalled anti-short cycle kit is recommended.

Refrigerant system

is designed to provide dependability. Liquid

filter dryers are used to promote clean, unrestricted operation.
Each unit leaves the factory with a full refrigerant charge. Refrig-
erant service connections make checking operating pressures
easier.

HIGH AND LOW PRESSURE SWITCHES

provide added reli-

ability for the compressor.

Evaporator and condenser coils

are computer-designed for

optimum heat transfer and cooling efficiency. The evaporator
coil is fabricated from copper tube and aluminum fins and is lo-
cated inside the unit for protection against damage. The con-
denser coil is internally mounted on the top tier of the unit.
Copper fin coils and pre-coated fin coils are available from the
factory by special order. These coils are recommended in appli-
cations where aluminum fins are likely to be damaged due to
corrosion. They are ideal for seacoast applications.

Low sound ratings

ensure a quiet indoor and outdoor environ-

ment with sound ratings as low as 72 dB. (See page 3.)

Easy to service cabinets

provide easy single-panel accessibility

to serviceable components during maintenance and installation.
The unit base with integrated drain pan provides easy ground lev-
el installation with or without a mounting pad. Convenient rigging

holds are provided to manipulate the unit on the jobsite. A nesting
feature ensures a positive unit base to roof curb seal when the unit
is roof mounted. A convenient 3/4-in. wide perimeter flange
makes frame mounting on a rooftop easy.

Standard metal duct covers

with insulation come with the unit

and cover the horizontal duct openings. These can be left in place
if the units are converted to downflow.

Downflow operation

is easily provided in the field to allow ver-

tical ductwork connections. The basepan utilizes knockout style
seals on the bottom openings to ensure a positive seal in the
horizontal airflow mode.

Integrated Gas Control (IGC) board

provides safe and efficient

control of heating and simplifies trouble-shooting through its
built-in diagnostic function.

Cabinets

are constructed of heavy-duty, phosphated, zinc-

coated prepainted steel capable of withstanding 500 hours in
salt spray. Interior surfaces of the evaporator/heat exchanger
compartment are insulated with cleanable semi-rigid insulation
board, which keeps the conditioned air from being affected by
the outdoor ambient temperature and provides improved indoor
air quality. (Conforms to American Society of Heating, Refriger-
ation and Air Conditioning Engineers No. 62P.) The sloped drain
pan minimizes standing water in the drain, which is provided with
an external drain fitting.

Louvered Grille

provides hail and vandalism protection.

574B

N

W

024

040

N

VS

Model Number

574B

– Single

Packaged Gas
Heating/Electric
Cooling

Electrical Supply
N

– 208/230-1-60

P

– 208/230-3-60

Fuel
W

– Natural Gas

P

– Propane Gas

Low NO

x

Indicator

N

– Low NO

x

Unit

Only used if ordering NO

x

units

Nominal Cooling Capacity
024

– 2 ton

030

– 2.5 ton (not yet available)

036

– 3 ton

042

– 3.5 ton (not yet available)

048

– 4 ton

060

– 5 ton

Heat Input Size
040

– 40,000

060

– 60,000

090

– 90,000

115

– 115,000

130

– 130,000

LEGEND

CU

— Copper

AL

— Aluminum

Options

BT

– AL evap, vinyl condens

CC

– AL evap, CU condens

CU

– CU evap & condens

TP

– Base unit with tin plated indoor coil

hair pins

TV

– TP with vinyl coating on outdoor coil

TC

– TP with AL indoor coil and CU/CU

outdoor coil

Only used if ordering an option

MODEL NUMBER NOMENCLATURE

Advertising