- 4 -

4 Operating keys

5 Selection and display of the unit of measurement
The operator can select the appropriate unit label from a printed sheet and this is then
displayed with background lighting. The label can be changed at any time.
Procedure:

Disconnect the unit from supply voltage.

Remove the front frame of the unit by hand.

Loosen the 4 front plate screws.

Press lightly on the back panel of the unit to push out the front side (display section) by a
few millimetres.

Cut the label with the required unit from the sheet supplied.

Insert the label into the slot on the side.

Press lightly on the front panel to push it back on.

Screw the front plate back in place.

Put the front frame back on.

HDA5500

MODE

MODE

%

1

3

2

4

Relais

1 2 3

Sensor

4-digit
digital display

LED display
of active
switching points

LED display
of active
sensor

Keys for adjusting the
switching points,
switch-back points and
the menu functions

Display of
unit of measurement
sensor 1, 2, 3 or 4

%

Front frame

Indication of unit (of measurement) using label from sheet