Terminal Block Connection Details
NOTE:
This option is intended for permanent installation

application only.

Remove the top panel (lid) of the dimmer pack chassis to access

the contractor termination area, where the required dimmer output

(load) terminals are located. To remove the top panel (lid), remove

the ten (10) SEMS #8-32 x 3/8" Philips pan head mountings

screws located on the sides and the six (6) #8-32 x 3/8" Philips

flat head mounting screws located on the top, using a Philips #2

screwdriver, and carefully lift the lid up. The cooling fan is mounted

on the lid, so be careful not to strain the fan wiring cable. If the fan

cable needs to be disconnected, carefully cut off the strain relief

wire tie and unplug the fan connector from the J10 PCB connector.

Be sure to save the mounting screws to secure the top panel (lid)

once the dimmer output (load) wiring terminations are complete.
In suitable locations on the rear panel of the relay pack chassis,

knockout suitable hole sizes for wire/conduit entry to the output

(load) terminals. Ensure an adequate fitting is used to secure the

conduit to the rear panel. Only use wire rated for the specifications

provided below. Route the wire directly from the conduit entry into

the output (load) terminals. Use a 3/16" flathead screwdriver to

torque the power terminals to the specifications provided below.
Each dimmer output (load) circuit (120VAC 1Ø 3-Wire) requires

three (3) conductors; one (1) for hot, one (1) for neutral and one

(1) for ground. There are six (6) hot terminals, six (6) neutral

terminals and six (6) ground terminals, one for each dimmer

output connection.
Once the dimmer output (load) wiring terminations are complete,

carefully reinstall the top panel (lid). If the cooling fan cable was

disconnected, be sure to reconnect it to the J10 PCB connector,

and install a wire tie for strain relief. Carefully slide the lid down

into place, making sure the fan cable does not get pinched in the

metalwork. Secure the lid using the mounting screws previously

removed. To ensure ground continuity between all chassis panels,

be sure to use the SEMS mounting screws with integral star

washers on the sides.

• Use wire size #14 to #8 AWG copper wire only, rated for

300V and 167°F (75°C) minimum.

• Strip insulation length to 0.4" (10mm).

• Torque connections to 13 - 16 IN-LBS (1.5 - 1.8 NM).

WARNING: For connection use copper wire only, rated for

167°F (75°C) minimum.

WARNING: Ensure all dimmer output terminal connections

are tightened to the torque specification provided,

before turning on the AC power supply!

WARNING: Ensure all chassis panels are secure before turning

on the AC power supply!

Load (Hot)

Terminals

Neutral

Terminals

Ground

Terminals