User interface – Johnson Systems J-PACK Series Dimmers User Manual

Page 14

Advertising
background image

WWW.JOHNSONSYSTEMS.COM

14

EXECUTE ESCAPE RESET

RUN ØA ØB ØC RxD ERROR

MENU

User Interface

All J-PACK Series dimmer packs are equipped with a user interface located

on the front panel of the chassis. The user interface provides access to all

programming and configuration settings. System status is easily visible on

the LCD display and LED indicators.
All of the programming is accomplished using four (4) switches. Within a few

minutes, most users will find the menu structure very intuitive and easy to

navigate. All configuration settings are automatically stored into an on-board

EEPROM.
LCD Display
The LCD display is capable of displaying 2 lines of 8 characters. A backlight

automatically comes on when activity is sensed. The LCD contrast can be

easily adjusted for optimum viewing. Refer to menu item “LCD VIEW” on

page 27 for further details.
Programming Switches
The MENU UP/DOWN ( ) switches are used for navigating through the

various system configuration menu items. They also allow for programming

of other specific parameters within a selected menu. Pressing and holding

either switch will speed up the scroll rate, which can be helpful to speed up

the configuration time.
The EXECUTE ( ) switch is normally used to select/enter a menu item,

advance forward within a selected menu item, or toggle between parameters

within a selected menu item.
The ESCAPE ( ) switch is normally used to back up within a selected

menu item one step at a time or exit the menu completely.
The RESET switch has two purposes. First, it allows for quick exit from a

menu item after a programming change and automatically puts the system

into normal run mode. Second, it provides a soft reboot for the systems

microcontroller.
The programming switches are backlit with blue LED’s. The LED’s

automatically turn on when activity is sensed. The LED intensity can be

adjusted in the “LED INT” menu. Refer to page 27 for further details.

NOTE: When the J-PACK Series dimmer pack is powered up, the

menus are “LOCKED!!” with access only to the basic system

configuration menus, which includes setting the DMX start address

as well as enabling or disabling the end-of-line DMX termination.

The menus need to be “UNLOCKED” to access the advanced

system configuration menus. To toggle between “LOCKED!!”

and “UNLOCKED” press and hold down the EXECUTE and then

ESCAPE switches at the same time for 4-5 seconds.

A detailed procedure for programming all system configuration

menu items can be found on page 18 to 27.

Advertising