PM = Pipe Mount
For pipe mounting, a bracket, C-clamp and safety cable are

provided and must be used to secure the dimmer pack to

standard pipe sizes from 1" to 2" (1.25" to 2.375" outside

diameter).

WARNING: Ensure the pipe is secure and rated adequately

for local rigging codes.

Ensure the safety cable is fastened correctly to

secure the dimmer pack.

WM = Wall Mount
For permanent applications, the dimmer pack can be mounted

to any wall surface capable of supporting its weight. Using the

four (4) mounting holes provided, 1/4" (6mm) screws or bolts

are required to fasten and secure the rack safely to the wall.

WARNING: Never mount the dimmer packs side by

side (vertically) without a minimum of 12"

of clearance between them. Always leave a

minimum of 6" of clearance from the dimmer

packs air intake and exhaust. Failure to comply

may cause thermal overheating.

RM = Rack Mount
For rack mounting, brackets are provided and used to secure

the dimmer pack in a standard 19" rack.

WARNING: Ensure there is sufficient ventilation provided

when mounting multiple dimmer packs within a

19" rack. The internal ambient temperature of

the rack must not exceed 104°F (40°C). Failure

to comply may cause thermal overheating.

Ensure there is adequate rear support provided

to maintain the dimmer pack position inside the

19" rack.