6 technical data – JUMO 709050 IPC IGBT Power Converter IPC 70/100A Operating Manual User Manual

Page 46

Advertising
background image

6 Technical data

46

[IGBT Power Converter 70/100A] 02.08

Power loss P

tot

(W)

It occurs in the form of thermal discharge at the cooling body of the power
converter.

v Chapter 3.3 „Ambient conditions“

Control accuracy

The regulation will eliminate supply voltage variations within the tolerances range
(+15%/-20%) with an accuracy of

Ϯ

0.5

%

Electrical connection

Control leads via plug-in screw terminals for conductor cross-sections from
0.5 to 2.5mm

2

, in the power section via screw terminals 10 to 50mm

2

.

protection rating

IP 20 as per EN 60 529

Protection class

Protection class I, with isolated control circuitry for connection to SELV circuits

Permissible ambient
temperature range

5 … 40°C (3K3 as per EN 60721-3-3)

Permissible storage
temperature range

-10 … +70°C (1K3 as per EN 60 721-3-1)

Cooling

forced convection, maximum inlet air temperature 35°C

Climatic conditions

Rel. humidity

≤ 5 to 85 % annual average, no condensation

3K3 as per EN 60721

Installation position

vertical

Operating conditions

The converter is designed as a built-in device as per EN 50178
Pollution degree 2, overvoltage category Ü III

Test voltage

as per EN 50178

Creepage distances

Control section to load circuit

≥ 5.5 mm

Control section to housing

≥ 5.5 mm

The converter can be connected to SELV circuits.
SELV = Separate Extra Low Voltage (safe low voltage)

Earth leaking current

The earth leakage current of the IPC power converter used with an EMC filter in
the supply cable is less than 3 mA (excluding any leakage current in the load).

Housing

Metal housing

Weight

approx.

17 kgs

Advertising