30. To accept changes, press Enter

When RS-422/485 four-wire operation is selected:

When RS-422/485 four-wire operation is selected the RS-422/485 switch
on the MES1B must be in the left position.

When RS-485 two-wire operation is selected:

• CP1 (configured in the next section under Modem/Configurable Pin

Settings) must be enabled to ensure Send Data control is implemented.

• The RS-422/485 switch on the MES1B must be in the right position.
• The multidrop bus is connected to Terminals 3 [DataB(+) to TDB(+)

terminal] and 4 [DataA(-) to TDA(-) terminal].

• No jumpers are required to bridge transmit and receive lines on the

terminal block

Serial Parameters

MES1A/B Serial Parameters must be set up to match the parameters of the
Modbus device connected to its serial interface. MES1A/B Serial Parameter
options include:

• Data rates from 300 bps to 115200 bps
• 7 or 8 data bits
• No, Even or Odd parity
• 1 or 2 stop bits.

To configure Serial Parameters:

31. At the

Enter serial parameters (9600,8,N,1)

prompt

o

To keep the current setting, press Enter

o

To change the serial parameters, type in new parameters in the

format

9600,8,N,1

32. To accept changes, press Enter

3) Modem/Configurable Pin Settings

There is only one configurable setting required in the Modem/Configurable
Pin Settings