Technical data – Lenze 8400 motec Mounting Instructions User Manual

Page 43

Advertising
background image

Technical data

General data and operating conditions

3

l

43

EDK84DGDVBxxx4 DE/EN/FR/ES/IT 5.3

Protection of persons and equipment

Enclosure

EN 60529

IP65
optional: IP66

in ready−for−use state:

l

Close unused bores for
cable glands with
blanking plugs!

l

Close unused connectors
with protection covers or
blanking plugs!

NEMA 250

Protection according to

l

Type 4

(Earth) leakage
current

EN 61800−5−1

> 3.5 mA AC,
> 10 mA DC

Observe the regulations and
safety instructions!

Total fault current

In TN systems the following earth−leakage circuit
breakers can be used:

Motor mounting

E84DGDVB3714

...

E84DGDVB1524

30 mA, type B

E84DGDVB2224

...

E84DGDVB7524

300 mA, type B

Wall mounting

E84DGDVB3714

...

E84DGDVB7524

300 mA, type B

Additional
equipotential bonding

M5 thread with terminal in the WU for connection of
a 16mm

@ PE cable

Protective insulation
of control circuits

EN 61800−5−1

Safe isolation from mains by double (reinforced)
insulation

Insulation resistance

EN 61800−5−1

Site altitude

0 ... 2000 m Overvoltage category III

2000 ... 4000 m Overvoltage category II

Short−circuit strength

EN 61800−5−1

Connection:

Motor

To a limited extent, the
controller is inhibited, error
acknowledgement required

Motor holding brake,
brake resistor

No

PTC, control terminals

Full

Earth−fault strength

EN 61800−5−1

Connection:

Motor (at controller
enable)

To a limited extent, the
controller is inhibited, error
acknowledgement required

Motor (during
operation)

No

Brake resistor, PTC

No

Starting current

£ 2 x I

N

Advertising