Settings

6

l

53

EDK84DGDVBxxx4 DE/EN/FR/ES/IT 5.3

Setting elements 0.37 ... 3 kW
The setting elements are located on the inner side of the drive unit.
Settings carried out via DIP1, DIP2, P2, P3, and P1 must be activated with DIP1/1.
The settings are accepted again at every mains connection. Thus, changes on
parameters made in the meantime may be overwritten.

0.37 ... 3 kW

E84DG041

E84DG044

Name

DIP1

Switch for basic setting of quick commissioning

DIP2

P1

Setting "Top Cover: Speed ... %"

P2

Setting "Speed ... %", (speed)

P3

Setting "Ramp ... s", (acceleration/deceleration time)

X70

Connection for USB diagnostic adapter E94AZCUS or diagnosis terminal

0

LED status display