Commissioning 7 – Lenze 8400 motec Mounting Instructions User Manual

Page 62

Advertising
background image

Commissioning

7

l

62

EDK84DGDVBxxx4 DE/EN/FR/ES/IT 5.3

Commissioning
Proceed step by step:

ƒ

Switch on the mains

ƒ

Observe status display

After a short initialisation time, the display must be blinking green.

ƒ

Deactivate requirements of the safety function

ƒ

Set controller enable

After the set starting time, the motor must rotate with the set speed.

ƒ

First check of the expected behaviour:

Direction of rotation?

Starting time?

Speed?

Speed control?

ƒ

Check of optional control functions:

Does the analog setpoint selection work?

Do the digital control signals, e.g. limit switches, work?

Does the connected motor holding brake work?

Does the change of direction of rotation work?

Does the requirement of the safety function work?

Do the control signals over fieldbus work?

ƒ

Switch off drive

Reduce speed

Inhibit controller enable

Switch off mains

Depending on the bus system of the communication unit, statuses are indicated
by means of an LED display. Detailed information can be found in the
communication manual for the bus system used.

LED

1 (green)

2 (green)

3 (red)

4 (red)

PROFIBUS

BUS STATE

MODULE STATE

BUS ERROR

MODULE ERROR

AS−i

SLAVE 1 READY

SLAVE 2 READY

SLAVE 1 ERROR

SLAVE 2 ERROR

EtherCAT

RUN

LINK/ACTIVITY

ERROR

LINK/ACTIVITY

(green)

PROFINET

BUS READY

LINK/ACTIVITY

1

(yellow)

BUS ERROR

LINK/ACTIVITY 2

(yellow)

EtherNet/I
P

MODULE STATE

NETWORK STATE

E84DG056_b

(red)

(green)

Advertising