Software operation

User Interface Dialogs
Registry "ACU State" − Show UPS State

2

l

10

LDCDP−EPC50ACU EN 4.0

2.3

User Interface Dialogs

2.3.1

Registry "ACU State" − Show UPS State

ACU USV V2.x:

Dialog Box

Value Range

Explanation

Type

Hardware Type

Power

OK/Fail

Input Voltage State; OK or Failure

UPS

On/Off

On: UPS functionality activated

Buffer Time [s]

0.00 ... 64.00 s Period of time to wait until a voltage failure is reported by the

ACU UPS control unit. Thus, voltage fluctuations are filtered
out.

Delay Time [s]

0 ... 240 s;

infinite

Maximum period of time the industrial PC can be fed by the
battery/capacitor pack, depending on the hardware.

ACU State

Current ACU State Display

Firmware Version

Displays the current ACU firmware version

)

Note!

A change in the UPS State is displayed with a delay.