2 operating conditions, Operating conditions – Lenze IPC Operating System Windows CE Thin Client User Manual

Page 6

Advertising
background image

Product description

Operating conditions

2

l

6

LDCDP−11999 EN 3.0

Further functions

Command line: The software supports the entry of commands via the CE command line
(

19)/( 20)

Network programs: In the software the IPConfig and Ping network programs are
implemented. These programs can be used for the configuration of the network. They are
called via the command line (see above).

Compact Flash memory card:The contents of the CF card in the Thin Client can be accessed
via the command line (see above) or via the FTP server (

23). The contents of the CF card

appear as the "storage" folder.

)

Note!

The memory card also contains the CE image and the persistent registry within
which all configuration data are saved ("REG" directory).
In order to reset the default setting of the Thin Client, the REG directory can be
renamed via the command line during runtime. At the next restart a new
registry is created.

2.2

Operating conditions

The use of the «Windows

â

CE Thin Client» software is permissible with Lenze Thin Clients

of the following types:

ƒ

Command Station CS 5800 TC − CS 9800 TC

ƒ

Embedded Line EL 1800 TC − EL 9800 TC

Advertising