MTS Multipurpose Simulated User Manual
Page 44
Value to Use for Simulation
Parameter
10%
Precrack Lower Least Squares Fit
Percentage
90%
Precrack Upper Least Squares Fit
Percentage
1000000 count
Precrack Cycle Limit
347.851 N/mm^1.5
Precrack Final Maximum K
The following list shows delta K parameter values.
Delta K Parameter Values
Value to Use for Simulation
Parameter
0.10 unitless
FCG Load Ratio
379.413 N/mm^1.5
FCG Delta-K Initial
-0.080 1/mm
Normalized K Gradient (C)
10 Hz
FCG Frequency
True Sine
FCG Wave Shape
The following list shows constant load parameter values.
Constant Load Parameter Values
Value to Use for Simulation
Parameter
0.1 unitless
FCG Load Ratio
0 N
FCG End Level 1
10 Hz
FCG Frequency
True Sine
FCG Wave Shape
The following list shows data storage parameter values.
Data Storage Parameter Values
Value to Use for Simulation
Parameter
0%
Precrack Save Percent Limit
44 MTS TestSuite
5.0 Running Simulation Tests