MTS Multipurpose Simulated User Manual

Page 44

Advertising
background image

Value to Use for Simulation

Parameter

10%

Precrack Lower Least Squares Fit
Percentage

90%

Precrack Upper Least Squares Fit
Percentage

1000000 count

Precrack Cycle Limit

347.851 N/mm^1.5

Precrack Final Maximum K

The following list shows delta K parameter values.

Delta K Parameter Values

Value to Use for Simulation

Parameter

0.10 unitless

FCG Load Ratio

379.413 N/mm^1.5

FCG Delta-K Initial

-0.080 1/mm

Normalized K Gradient (C)

10 Hz

FCG Frequency

True Sine

FCG Wave Shape

The following list shows constant load parameter values.

Constant Load Parameter Values

Value to Use for Simulation

Parameter

0.1 unitless

FCG Load Ratio

0 N

FCG End Level 1

10 Hz

FCG Frequency

True Sine

FCG Wave Shape

The following list shows data storage parameter values.

Data Storage Parameter Values

Value to Use for Simulation

Parameter

0%

Precrack Save Percent Limit

44 MTS TestSuite

5.0 Running Simulation Tests

Advertising