Transducer Interface
SWIFT
®
Mini TI
Hardware Overview
25
The TI conditions the transducer signals, producing seven analog output signals
proportional to the following values:
•
Longitudinal force (Fx)
•
Lateral force (Fy)
•
Vertical force (Fz)
•
Overturning moment (Mx)
•
Driving/Braking moment (My)
•
Steering moment (Mz)
•
Angle (
θ) or Angular Velocity (ω)
Analog signals
The force, moment, and angular velocity signals are output from the TI in the
form of ±10 V
1
full scale analog signals. These signals can be used by most data
acquisition systems.
The angle output is an analog voltage that is proportional to angular position. At
0° the output is 0 V. At 360°, the output is 5 V.
Coordinate
System
Offset
Matrix
1.
Standard from MTS. Other full-scale output voltages can be evaluated and may be
provided at special request.