25

The TI conditions the transducer signals, producing seven analog output signals
proportional to the following values:

Longitudinal force (Fx)

Lateral force (Fy)

Vertical force (Fz)

Overturning moment (Mx)

Driving/Braking moment (My)

Steering moment (Mz)

Angle (

θ) or Angular Velocity (ω)

Analog signals

The force, moment, and angular velocity signals are output from the TI in the

form of ±10 V

1

full scale analog signals. These signals can be used by most data

acquisition systems.

The angle output is an analog voltage that is proportional to angular position. At
0° the output is 0 V. At 360°, the output is 5 V.

Coordinate

System

Offset

Matrix

1.

Standard from MTS. Other full-scale output voltages can be evaluated and may be
provided at special request.