Troubleshooting – Multiquip WM70SH8C User Manual

Page 34

Advertising
background image

page 34 — WM70SH5C/WM70SH8C Mixer • operaTion and parTS Manual — rev. #0 (06/07/11)

Mixer Troubleshooting

Blades will not rotate.

Worn or defective V-belt?

Replace V-belt.

Adjustment lever mis-aligned?

Check position of adjustment lever.

Adjust if necessary.

Material leaking from drum ends.

Worn or defective paddle shaft seals? Replace seals.

Drum difficult to discharge (tilt)

Defective or worn drum support

brackets?

Apply grease to bracket or replace.

Blades adjusted too tight.

Adjust blades until they almost touch

side walls of drum.

trOublesHOOtinG