page 34 — LT6K LIgHT TOWeR • OpeRaTIOn manuaL — Rev. #1 (08/28/14)

operation

TuRnIng On THe LIgHTs

1. Place the main circuit breaker, CB1 (Figure 18) on the

control panel to the

On position.

Figure 18. Main Circuit Breaker (CB1)

2. Place circuit breaker, CB2 (Figure 19) on the control

panel to the

On position. This will turn on the top 2

lights.

3. Next, place circuit breaker, CB3 (Figure 19) on the

control panel to the

On position. This will turn on the

bottom 2 lights.

Figure 19. Lamp Circuit Breakers (CB2/CB3)

4. Wait a few minutes for the ballasts to activate. Observe

that all lights are

On.

5. If all the light circuit breakers (CB2 and CB3) are in the

On position (up), then all of the lights should be on.

6. If any of the lights are not on, refer to the troubleshooting

section of this manual.

7. Close all cabinet doors.

OFF

OFF

CB1

CB2

CB3

NOTICE

neveR operate the light tower with the engine

compartment doors open. Operation with the doors

open may cause insufficient cooling to the unit, and

damage may result.

sTaRTIng THe engIne

1. Open the access panel door on the

fuel side of the

light tower. Set the door latch in place to hold the door

open (up).

2. Insert the ignition key into the ignition key switch

(Figure 17). Turn the ignition key clockwise one click

to the

On position. The preheat indicator lamp will

light. Wait for this indicator lamp to go

OFF. When the

indicator lamp goes

OFF, the glow plugs have been

preheated and the engine can now be started.

Figure 17. Ignition Switch

3. Continue turning the ignition key all the way clockwise

When the engine has started, release the key.

4. Before placing the light tower into actual operation, let

the engine run for 3-5 minutes. Check any abnormal

sounds or smells that would be associated with a

defective light tower. If any abnormal conditions occur,

shut down the engine and correct the problem.

CauTIOn

neveR start the engine with any circuit breakers in

the

On position. Disconnect all loads before starting.

WaRnIng

neveR place hands near the V-belt or fan

blades while the engine is running.

WaRnIng

The engine's exhaust contains harmful

emissions.

ALWAYS ventilate the exhaust

when operating inside tunnels, excavations

or buildings. Direct exhaust away from

nearby personnel.