Maintenance – Multiquip LT6K User Manual

Page 41

Advertising
background image

LT6K LIgHT TOWeR • OpeRaTIOn manuaL — Rev. #1 (08/28/14) — page 41

maintenance

5. Rethread the cable through the pulley and reattach the

cable to the ball socket pin.

6. Raise and lower the mast several times to verify correct

operation.

seRvICIng THe masT exTensIOn CaBLe sYsTem:

To replace the cable in the

mast extension cable system

(Figure 30), use the following steps:

Figure 30. Mast Extension Cable System

1. Lower the mast to the horizontal resting position.
2. Inspect the cable clamps, pulleys, and other components

for worn or damaged parts. If either of the cables on

the mast needs to be replaced, they should both be

replaced at the same time.

3. Disassemble the mast by disconnecting the cables

from the mast and sliding the sections apart. The lower

cable can be disconnected from the winch.

4. There are two pulleys in the mast raise/lower cable

system. They should be removed and replaced if worn

or damaged. Worn or damaged pulleys can cause

premature cable failure.

5. Reassemble the mast extension cable system by

connecting the cable to the bottom of the upper mast

and sliding the upper mast into the opening of the

center mast. Connect the second cable to the bottom

of the center mast and slide the center mast into the

opening of the lower mast, observing proper lifting

techniques.

CENTER

MAST

PULLEY

ROUTE TO

HAND WINCH

LOWER

MAST

PULLEY

UPPER

MAST

CENTER

MAST

LOWER

MAST

LOWER

MAST

SHACKLE

WaRnIng

The mast sections are heavy and awkward to handle.

Use proper lifting devices and procedures when

servicing the mast and its components.

6. Route the upper mast cable through the center mast

pulley and connect the free end of the cable to the

lower mast ankle shackle. Route the center mast

cable through the lower mast pulley and connect the

free end of the cable to the hand winch at the bottom

of the lower mast.

7. Raise, extend, retract and lower the mast several times

to verify correct operation.

STORAGE

For storage for over 30 days, the following is required:

„

Fill the fuel tank completely. Treat with fuel stabilizer if

necessary.

„

Completely drain oil from the crankcase and refill if

necessary with fresh oil.

„

Clean the entire light tower.

„

Disconnect the negative terminals of the battery and

cover it, or remove and store it separately.

„

If the ambient temperature is expected to drop below

0°C (32°F), add antifreeze to the radiator.

„

Cover the light tower and store in a clean, dry place away

from children and unauthorized personnel.

RemOvaL FROm LOng TeRm sTORage

If light tower is going to be used again after long term

storage, perform the following.

„

Apply oil to the engine valve and rocker arms, and

examine the operating condition of the valves.

„

Change the oil in engine oil pan.

„

Replace all the filters.

„

Flush the inside of the cooling system.

„

Drain the water from the fuel tank and bleed the air from

the fuel system.

„

If the engine has not been started for more than one

year, contact your Kohler distributor to have engine

overhauled.

Advertising