Switching the installed header sensors on or off – MacDon M205 Operators Manual User Manual

Page 138

Advertising
background image

OPERATOR’S STATION

Switching the Installed Header Sensors On or Off

You can selectively enable or disable header sensors in the event of a malfunction or as part of a
troubleshooting routine.

NOTE:

• Header MUST be attached to the windrower to perform this procedure. The cab display module (CDM)

automatically adjusts its programming for each header. For more information, refer to

4.5 Attaching and

Detaching Headers, page 202

.

• Disabled sensors flash the word SENSOR on CDM during regular operation.

1. Turn ignition key to RUN, or start the engine. Refer to

Starting the Engine, page 152

.

2. Press PROGRAM (A) and SELECT (C) on cab display

module (CDM) to enter Programming Mode.

• WINDROWER SETUP? is displayed on the

upper line.

• NO/YES is displayed on the lower line.

3. Press SELECT (C) until DIAGNOSTIC MODE? is

displayed on the upper line.

• NO/YES is displayed on the lower line.

4. Press right (B) arrow to select Yes. Press SELECT (C).

• VIEW ERROR CODES? is displayed on the

upper line.

Figure 3.153: CDM Programming Buttons

5. Press SELECT (B) until ENTER SENSOR SETUP? is

displayed on the upper line.

• NO/YES is displayed on the lower line.

6. Press right (A) arrow to select Yes. Press SELECT (B).

• KNIFE SPEED SENSOR is displayed on the

lower line.

• ENABLE/DISABLE is displayed on the lower line.

Figure 3.154: Selecting Diagnostic Functions

169887

122

Revision A

Advertising