Replacement Thermostat Wiring

1.

2.

3.

If you are replacing a thermostat, make note

of the terminal connections on the thermo-

stat that is being replaced. In some cases the

wiring connections will not be color-coded.

For example, the green wire may not be

connected to the G terminal.

Loosen the terminal block screws. Insert

wires then retighten terminal block screws.

Place nonflammable insulation into wall

opening to prevent drafts.

This thermostat requires a 24V Common Wire

to the C terminal.

All components of the control

system and the thermostat

installation must conform to

Class II circuits per the NEC

Code.

Use shielded or non-shielded

18-22 gauge thermostat wire.

WIRING

Wire Specifications

Warning

EMHEAT

EMHEAT

DO NOT OVER TIGHTEN TERMINAL

BLOCKS. CAN CAUSE DISTORTIONS

AND MALFUNCTIONS.

Warning

Note:

Devices such as a float switch that mechanically break circuits should

be installed so that they break the control wire (Y) not the power (R).
Interrupting the power circuit will shut off power to the thermostat completely
and not allow it to operate.