Technician setup menu, Display light – Pro1 T855i Installation manual User Manual

Page 9

Advertising
background image

Contractor Call Number Note:

Use the plus or minus key to select the desired number and the FAN

or SYSTEM key to move from one character to another. If contractor Call Number is selected ON,

your phone number will show in the display if there has been a continuous call for heating or cooling

for 24 hours or if the light button is held down for 3 seconds. To remove the phone number from the

display, hold the light button down for 3 seconds.

9

LCD Will Show

Adjustment Options

Factory Default Setting

TECHNICIAN SETUP MENU

TECH SETUP

STEPS CONTINUED

ON THE NEXT PAGE

Tech Setup Steps (Continued from the previous page)

AUTO

AUTO

l

NEXT preV done

off

CONTRACTOR NUMBER

NEXT preV done

0000000000

NEXT preV done

call

on

NEXT preV done

beep

off

NEXT preV done

heat pump

5 y5

se

cool off heat

off

AG

GAS AUX heat

Next preV done

Next preV done

2H2c

heat cool stgs

Next preV done

NEXT preV done

Contractor

Call Number

Beep

Heat Pump

System

Set

Gas Auxiliary

for Heat Pump

When any key is

pressed an audible

beep will sound.

You can choose

ON or OFF

If ON is selected

the beep will

sound.

If OFF is selected,

there is no sound.

OFF

When turned on

the thermostat

will operate a

heat pump.

1. EM.Heat will

show as an option

in the system

switch.

2. Y will be first

stage of heat &

cool, W/E will be

emergency heat

relay & W2 will

be auxiliary heat

OFF configures

the thermostat

for non heat

pump systems.

ON configures

the thermostat

for heat pump

systems.

Heat - Off - Cool

Set system switch for
your application.

COOL
HEAT
AUTO (auto changeover)
EHT (emergency heat-
heat pump only)

Use the or

key until the desired

application is

flashing.

OFF

This option will turn

the heat pump off 45

seconds after the

auxiliary heat relay

turns on.

For 2 heat

applications, the first stage

will turn off 45 seconds

after the auxiliary stage

turns on.

For 3 heat

applications, the first

and second stage will

turn off 45 seconds

after the auxiliary

stage turns on.

For heat pump

systems that are

“dual fuel” (use a gas

furnace for auxiliary

stage heat) you can

turn this feature on

to turn off the heat

pump when the

auxiliary stage of

heating has been

called for.

Allows you to put

your phone

number in the

display.

You can choose

ON or OFF

See note below on

operation.

If selected ON , you

will see the input

screen after pressing

next step.

OFF

Display

Light

The display light can

be configured to

operate 3 different

ways. To come on

only when the Light

Key is pressed, when

Any Key is pressed,

or stay on ALL of

the time.

You can configure this
thermostat to operate up
to a 2 heat/2 cool
conventional, or up to
a 4 heat/2 Cool heat
pump system.

First set the heat stages
then set the cool stages

Stages of Heat will be

flashing first. Set your

number of heat stages

then press Next. Stages

of cool will now be

flashing. Set your

number of cool stages.

See page 6 for terminal

references.

Stages of Heat

and Cool

2 Stages

‘OFF’ - Only light

key on

‘AUTO’- Any key ON

‘ON’ - Always On

ON

Pre Occupancy

Fan

The pre occupancy

fan settings will

energize the fan

before the occupied

time to provide

ventilation prior to

scheduled

occupancy.

This feature only

shows if technician

setup step for time

periods is set to

2C or 4C.

You can select the

pre occupancy fan

from OFF, 1, 2, or

3 hours.

If 1, 2, or 3 is

selected, the fan

will turn on that

many hours prior

to the scheduled

occupied time

period.

OFF

PRE OCCUPY FAN

COOL HEAT

HEAT- (heat only)

COOL- (cool only)

COOL HEAT AUTO -

(auto changeover)

(heat pump)

COOL HEAT EHT

COOL HEAT EHT AUTO