Connection Mode

Connection Mode

Select from “Always Online” and “Connect On Demand”.
Always Online: Auto activates PPP and keeps the link up after power on.
Connect On Demand: After selection this option, user could configure
Triggered by Serial Data, Triggered by Periodically Connect and Triggered by
Time Schedule.
Note: If you select several connect on demand polices, router only have to
meet one of them to be triggered.

Connect
On
Demand

Redial Interval

Router will automatically re-dial with this interval when it fails
communicating to peer via TCP or UDP.

30

Max Retries

The maximum retries times for automatically re-connect when router fails
to dial up.
After maximum retries, router will reboot the wireless module. If router still
cannot dial up successfully, it will try to switch to the other SIM card. Then
router will re-connect with the other SIM card with maximum retries.
After successful connection, the Max Retries counter will be set to 0.

3

Inactivity Time

Configurable after “Connect On Demand” was selected.
This field specifies the idle time setting for GPRS/3G auto-disconnection and
trying to revert back to preferred SIM card.
0 means timeless.

0

Serial Output Content

The content which output to the serial device which connect to router and
inform it that router is ready to receive serial data.

Null

Triggered by Serial Data

Tick this check box to allow router automatically connects to cellular
network from idle mode when there is data comes out from serial port.

Enable

Triggered by Tel

Tick this check box to allow router automatically connects to cellular
network from idle mode when make a voice call to router.

Disable

Triggered by SMS

Tick this check box to allow router automatically connects to cellular
network from idle mode when send a specific SMS to router.

Disable

SMS Connect Command

Users shall send this specific SMS to trigger router to connect to cellular
network.

Null

SMS

Disconnect

Command

Users shall send this specific SMS to trigger router to disconnect to cellular
network.

Null

SMS Connect Reply

When router connects to cellular network, it will automatically send out this
SMS to specific users (set in the Phone Group).

Null

SMS Disconnect Reply

When router disconnect from cellular network, it will automatically send out
this SMS to specific users (set in the Phone Group).

Null

Phone Group

Click to add Phone Group to Set specific users’ phone Book and which
phone Group they are belonged to.

Null

Triggered by IO

Tick this check box to allow router automatically connects to cellular
network from idle mode when there is a DI (DI_1) alarm input.

Disable

Periodically Connect

Tick this check box to allow router automatically connects to cellular
network with preset interval which you preset in Periodically Connect
Interval
.

Enable

Advertising