Robustel M1000 User Guide User Manual

Page 39

Advertising
background image

Robustel GoRugged M1000 User Guide


RT_UG_M1000 _v.2.0.0

20.12.2013

38 / 83

Confidential

parameters when triggered.
Null: Do nothing.

Alarm Off Action

Digital Output acts when alarm recovered.
Selected from OFF, ON, Pulse, Null.
OFF: Open when triggered.
ON: Short contact when triggered.
Pulse: Generates a square wave as specified in the pulse mode
parameters when triggered.
Null: Do nothing.

Null

Status When Power
On

Specify the Digital Output status when power on.
Selected from OFF, ON.
OFF: Open.
ON: Short contact.

Null

Keep On

Available when digital output Alarm On Action/Alarm Off Action
status is ON, input the Digital Output keep on status time.
Input from 0 to 255 seconds. (0=keep on until the next action)

0

Triggering Alarm

Available when enable SMS Control in Alarm Source.
Input the SMS content to enable “Alarm On Action” by SMS. (70 ASIC
II char max)

Null

Recovering Alarm

Available when enable SMS Control in Alarm Source.
Input the SMS content to enable “Alarm Off Action” by SMS. (70 ASIC
II char max)

Null

Phone Group

The alarm SMS will send to specified phone group.
Each phone group include up to 10 phone numbers.

Null

Low

Available when enable Pulse in Alarm On Action/Alarm Off Action.
In Pulse Output mode, the selected digital output channel will
generate a square wave as specified in the pulse mode parameters.
The low level widths are specified here.
Input from 1 to 30000 ms.

1

High

Available when enable Pulse in Alarm On Action/Alarm Off Action.
In Pulse Output mode, the selected digital output channel will
generate a square wave as specified in the pulse mode parameters.
The high level widths are specified here.
Input from 1 to 30000 ms.

1

Output

Available when enable Pulse in Alarm On Action/Alarm Off Action.
The number of pulses, input from 0 to 30000. (0 for continuous pulse
output)

1

Delay

Available when enable Pulse in Alarm On Action/Alarm Off Action.
The first pulse will be generated after a “Delay”.
Input from 0 to 30000ms. (0=generate pulse without delay)

0

Advertising