Example of wiring a control to twin conductor, Twin conductor, Turn off breaker – WarmlyYours TempZone FLEX (Twin) Conductor 120V or 240V User Manual

Page 9

Advertising
background image

Example of Wiring a Control to Twin Conductor

8

Twin Conductor

Turn off Breaker

1. Using a wirenut, attach line (240V) or neutral (120V)

from breaker box to top, red wire on the thermostat

labeled: “L2(N)”.

2. Using a wirenut, attach line (240V & 120V) from

breaker to bottom, black wire labeled: “L1(L)”.

3. Using a wirenut, attach red wire (yellow for 120V)

from heating, roll to the lower, red wire labeled: “load

”.

4. Using a wirenut, attach black wire to upper black

wire labeled: “Load ”.

5. Using a wirenut, attach the ground wire of heating

roll to the ground wire in the wallbox.

6. Turn on breaker.

Black

HOT

FROM POWER SOURCE 120V & 240V

HOT (240V) or

NEUTRAL (120V)

HOUSE GROUND

Red (240) or

Yellow (120) Wires

Red

Black

Red

Copper

Ground

Black Lead

THERMOSTAT

1

2

3

4

5

C/O INDIA Made by Thermopads Pvt. Ltd. for WarmlyYours.com Inc.

ENREGISTRE

LISTED

C

US

RADIANT HEATING PANEL UNIT

UNITE DE PLANCHER

CHAUFFANT ELECTRIQUE

8PA5

TempZone Electric Floor
Heating Panel
Plancher Chauffant Electrique
For installation in an
adhesive bed, self leveling or
mortar cement
Installation avec ciment, mortier
colle ou colle a carrelage

SKU S/NO

Resistance / Ohm

Spez. output W/sqf

Puissance au pied carre : 15 W

Core to Core

: 105.3 Ohm Voltage : 120V/60 Hz

Tension a Tension

Length / ft

Grd Sheath to Grd Sheath : 1.02 Ohm

Longueur en pieds : 9

Prise de terre a Pdt

Width / ft

Largeur en pieds : 1.0

Output Unit W : 135

Puissance de l’unite

Secondary

Flouropolymer

Insulation

Primary

Flouropolymer

Insulation

Solid

Conductor

Wire

Metal Braiding

Connected to Ground

Double Gang Box with a

Single Gang Mudring

Load

L2 (N)

L1 (L)

Advertising