Step 11: install the drive cover(s), Specifications – Rockwell Automation 20D-MDI-C1 Multi-Device Interface Option Board for PowerFlex 700S Drives User Manual

Page 18

Advertising
background image

18

Multi-Device Interface Option Board for PowerFlex® 700S Drives

Step 11: Install the Drive
Cover(s)

Phase I Drives Frames 1 - 6

The procedure for installing the covers on Phase I drives, frames 1 - 6, is the
reverse of removal. Refer to

Remove the Drive Cover(s) on page 3

.

Phase II Drives Frames 1 - 6

The procedure for installing the covers on Phase II drives, frames 1 - 6, is
the reverse of removal. Refer to

Remove the Drive Cover(s) on page 3

.

Frame 9 Size Drives

The procedure for installing covers on frame 9 size drives is the reverse of
removal. Refer to

Frame 9 Size Drives on page 4

.

Frame 10 - 13 Size Drives

The procedure for installing covers on frame 10 - 13 size drives is the
reverse of removal. Refer to

Frame 10 - 13 Size Drives on page 4

.

Specifications

MDI Option Board Specifications

Consideration

Description

Rotary Encoder Voltage Supply

11.5V dc @ 130 mA

Rotary Encoder Hi-Resolution
Feedback

Sine/Cosine 1V P-P Offset 2.5

Rotary Encoder Maximum Cable
Length

90m (295 ft.)

Rotary Encoder RS-485 Interface The MDI Option board obtains the following information via the

Hiperface RS-485 interface shortly after power-up:

Address

Command Number

Mode

Number of turns

Number of Sine/Cos cycles

Checksum

Registration Inputs

high speed 12-24V dc sinking digital inputs

Customer-I/O plug (P1)

Allen-Bradley PN: S94274917
Weidmuller PN: 67601782