Rockwell Automation 1336T FORCE to PowerFlex 700S Phase II Drive Conversion Guide User Manual

Page 13

Advertising
background image

1336 FORCE™ To PowerFlex® 700S Phase II AC Drive Conversion Guide

13

c4

ND Rating

600V, 60Hz Input

Code

Amps

Hp

1P7

1.7

1

2P7

2.7

2

3P9

3.9

3

6P1

6.1

5

9P0

9

7.5

011

11

10

017

17

15

022

22

20

027

27

25

032

32

30

041

41

40

052

52

50

062

62

60

077

77

75

099

99

100

125

125

125

144

144

150

170

170

150

208

208

200

261

261

250

325

325

350

385

385

400

416

416

450

460

460

450

502

502

500

590

590

600

650

650

700

750

750

800

820

820

900

920

920

1000

1K0

1030

1100

1K1

1180

1300

Note: CE Certification testing has not been
performed on 600V class drives Frames 1…4.

c5

ND Rating

690V, 50 Hz Input

Code

Amps

kW

052

52

45

060

60

55

082

82

75

098

98

90

119

119

110

142

142

132

170

170

160

208

208

200

261

261

250

325

325

315

385

385

355

416

416

400

460

460

450

502

502

500

590

590

560

650

650

630

750

750

710

820

820

800

920

920

900

1K0

1030

1000

1K1

1180

1100

Note: CE Certification testing has not been
performed on 600V class drives Frames 1…4.

e

HIM

Code

Operator Interface

0

Blank Cover

2

Digital LCD

3

Full Numeric LCD

5

Prog. Only LCD

C

Full Numeric LCD,

Door Mount

Frames 10 & up only.

f

Documentation

Code

Documents

E

Quick Start Guide

N

No Documentation

g

Brake

Code

w/Brake IGBT

s

e

Y

Y

o

N

N

Brake IGBT is standard on Frames 1-3 and
optional on Frames 4-9 ONLY.

h

Brake Resistor

Code

w/Resistor

Y

Yes

o

N

N

Not available for Frame 3 drives or larger.

j

Comm Slot

Code

Version

N

None

C

DPI ControlNet (Coax)

D

DPI DeviceNet

E

DPI EtherNet/IP

R

DPI RIO

S

DPI RS-485 DF1

1

DriveLogix ControlNet (Coax)

2

DriveLogix ControlNet Redundant

(Coax)

3

DriveLogix ControlNet (Fiber)

4

DriveLogix ControlNet Redundant

(Fiber)

5

DriveLogix DeviceNet (Open Conn.)

6

DriveLogix EtherNet/IP

k

Control Options

Code

Control

Option

Logic

Expansion

Synch

-Link

Cassette

A

Phase

II

No

No

Expanded

B

Phase

II

No

Yes

Expanded

C

Phase

II

Yes

No

Expanded

D

Phase

II

Yes

Yes

Expanded

G

Phase

II

N/A

No

Slim

H

Phase

II

N/A

Yes

Slim

l

Feedback

Code

Option

N

No Option

A

Resolver

B

Stegmann Hi-Resolution Encoder

C

Multi-Device Interface

E

2nd Encoder

S

Safe-Off (w/2nd Encoder)

Expanded cassette required.

One encoder interface is included with the
base drive.

m

Additional Config.

Code

Description

E

Phase II Control

K

Phase II DriveLogix5730

L

Phase II DriveLogix5730

w/EtherNet/IP

This is an embedded EtherNet option that is
only available with DriveLogix5730.

i

Emission

Code

CE Filter

CM Choke

A

Yes

Yes

B

Yes

No

N

§

No

No

Frames 1-6 Only.

Frames 9 & up Only.

§

For use on a high resistive ground or
ungrounded distribution system (Frame 9 only).

Note: CE Certification testing has not been
performed on 600V class drives Frames 1…4.

d

Enclosure

Code

Enclosure

A

IP20, NEMA Type 1

B

§

IP21, NEMA Type 1,

MCC

N

Open/IP00

Frames 9 & up Only.

§

Frames 10-12 Only.

Advertising
This manual is related to the following products: