Frame to ac drive rating cross reference, 400v ac input (using 700s kw ratings values), 480v ac input (using 700s hp ratings values) – Rockwell Automation 1336T FORCE to PowerFlex 700S Phase II Drive Conversion Guide User Manual

Page 14

Advertising
background image

1336 FORCE™ To PowerFlex® 700S Phase II AC Drive Conversion Guide

14

Frame to AC Drive Rating Cross Reference

400V AC Input (using 700S kW ratings values)

480V AC Input (using 700S HP ratings values)

ND kW

HD kW

ND Cont.

Output Amps 1336 Frame

PF 700S Frame

0.75

0.55

2.1

B

1

1.5

1.1

3.5

B

1

2.2

1.5

5.0

B

1

4.0

3.0

8.7

B

1

5.5

4.0

11.5

B

1

7.5

5.5

15.4

B

1

11

7.5

22

B

1

15

11

30

B

2

18.5

15

37

B

2

22

18.5

43

B

3

30

22

56

B, C

3

37

30

72

C

3

45

37

85

C

4

55

45

105

C, D

5

55

45

125

D

5

75

55

140

D

6

90

75

170

D, E

6

110

90

205

E

6

132

110

260

E

6

132

110

261

E

9

160

132

300

E

9

200

160

385

E

10

250

200

460

E, F, G

10

250

250

500

F, G

10

315

250

590

F, G

11

355

315

650

F, G

11

400

355

730

G

11

ND HP

HD HP

ND Cont.

Output Amps 1336 Frame PF 700S Frame

1

0.75

2.1

B

1

2

1.5

3.4

B

1

3

2

5.0

B

1

5

3

8.0

B

1

7.5

5

11

B

1

10

7.5

14

B

1

15

10

22

B

1

20

15

27

B

2

25

20

34

B

2

30

25

40

B, C

3

40

30

52

B, C

3

50

40

65

C

3

60

50

77

C

4

75

60

96

C, D

5

100

75

125

D

5

125

100

156

D

6

150

125

180

D, E

6

200

150

248

E

6

200

150

261

E

9

250

200

300

E

9

300

250

385

E

10

350

300

460

E, F, G

10

450

350

500

F, G

10

500

450

590

F, G

11

500

500

650

G

11

600

500

730

G

11

700

600

820

H

12

800

700

920

H

12

Advertising
This manual is related to the following products: