Step 3 - basic programming, Menu structure hierarchy stopped – Rockwell Automation 150 SMC Flex Quick Start User Manual

Page 11

Advertising
background image

SMC™ Flex Quick Start 11

Step 3 - Basic Programming

The SMC-Flex controller can be programmed with the built-in keypad and LCD display or with an optional
Bulletin 20-HIM-xx LCD human interface module.

Parameters

Diagnostics

Preferences

Memory

Storage

Log In *

See File Structure Below for
additional details

Alarms

Faults
Device Revision

Change Password
User Dspl Line
User Dspl Time
User Dspl Video
Reset User Display

Reset to Defaults

Enter Password

(* - Only Active when a password is used)

Main Menu

Monitoring

Volts Phase A-B
Volts Phase B-C
Volts Phase C-A

Current Phase A
Current Phase B
Current Phase C
Watt Meter
Kilowatt Hours
Elapsed Time
Meter Reset
Power Factor
Mtr Thermal Usage

Set Up

Motor Protection

Communications

Utility

Linear List

Basic

SMC Option
Motor Connection
Line Voltage
Starting Mode
Ramp Time

Initial Torque

Cur Limit Lvl
Kickstart Time
Kickstart Level
Stop Input
Option 1 Input
Option 2 Input
Stop Mode
Stop Time
Overload Class
Service Factor
Motor FLC
Overload Reset

Aux1 Config
Aux2 Config
Aux3 Config
Aux4 Config

Parameter Mgt

Metering

Overload

Underload

Undervoltage

Overvoltage

Unbalance

Jam

Stall

Ground Fault

PTC

Phase Reversal

Restart

Overload Class
Service Factor
Motor FLC
Overload Reset
Overload A Lvl
Parameter Mgmt

Underload F Lvl
Underload F Dly
Underload A Lvl
Underload A Dly
Parameter Mgmt

Undervoltage F Lvl
Undervoltage F Dly
Undervoltage A Lvl
Undervoltage A Dly
Parameter Mgmt

Overvoltage F Lvl
Overvoltage F Dly
Overvoltage A Lvl
Overvoltage A Dly
Parameter Mgmt

Unbalance F Lvl
Unbalance F Dly
Unbalance A Lvl
Unbalance A Dly
Parameter Mgmt

Jam F Lvl
Jam F Dly
Jam A Lvl
Jam A Dly

Parameter Mgmt

Stall Delay
Parameter Mgmt

Gnd Flt Enable
Gnd Flt Lvl
Gnd Flt Dly
Gnd Flt Inh Time
Gnd Flt A Enable
Gnd Flt A Lvl
Gnd Flt A Dly
Parameter Mgmt

PTC Enable
Parameter Mgmt

Phase Reversal
Parameter Mgmt

Starts Per Hour
Restart Attempts
Restart Delay
Parameter Mgmt

Comm Masks

Data Links

Logic Mask
Parameter Mgmt

Data In A1
Data In A2
Data In B1
Data In B2
Data In C1
Data In C2
Data In D1
Data In D2
Data Out A1
Data Out A2
Data Out B1
Data Out B2
Data Out C1
Data Out C2
Data Out D1
Data Out D2
Parameter Mgmt

Language

Motor Data

Language
Parameter Mgmt

Motor FLC
Motor ID
Parameter Mgmt

Linear List

All Parameters

Menu Structure Hierarchy

Stopped

---

0.0
0.0
0.0

Amps

Volt

%MTU

Power Up and Status Display

Note:

Depending on the SMC option, additional

parameters may appear in some menus

The external HIM has similar programming

operation to the built-in HIM, however some
differences do exist.

The built-in HIM can not be used to program

other DPI devices (i.e. Device Select)

Advertising