Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual

Page 103

Advertising
background image

Publication 1398-5.0 – October 1998

Interfaces

6-39

3. Verify the computer can communicate with the drive by perform-

ing the following:

• Switch drive power to ON

• Start ULTRA Master on the attached PC

• Choose

CANCEL

from the Drive Select window

• Select

C

ommunications

from the menu

• Select

P

C Set Up

from the pull down menu

• Verify the port settings, and if necessary, change them, then

choose

OK

.

• Select

C

ommunications

from the menu

• Select

R

ead Drive Parameters

from the pull down menu

• Choose

OK

in the Drive Select window.

4. Verify that ULTRA Master reads the drive parameters. If not,

refer to “Troubleshooting” on page 11-6.

The cable diagrams provide wiring examples for both 9 pin and 25 pin
serial ports from an IBM compatible personal computer to the drive.
RS-232 pin-outs vary between computer manufacturers. Check the
hardware reference manual of your machine to ensure correct signal
connections between the computer and the drive.

Advertising