background image

Publication 1398-5.0 – October 1998

Interfaces

6-33

BX+ and BX-,
or
DIR+ and DIR-,
or
CCW (Step Down+)
and
CCW (Step Down-)

J3-16 (+)
J3-17 (-)

Auxiliary Channel B(+) and B(-). Differential,
quadrature, or TTL level encoder input. The
signals are selectable as BX+ and BX-, or
DIR+ and DIR-, or CCW (Step Down+). and
CCW (Step Down-).

For encoder information refer to “Quadrature
Interface Specifications” on page 6-20 and

Figure 6.23, 6.24, 6.25, 6.26, 6.27, 6.28 and
6.29.

For stepper information refer to“Step/Direc-
tion and CW/CCW (Step Up/Step Down)
Interface Specifications” on page 6-24 and

Figure 6.30, 6.31, 6.32 and 6.33.

J1-16 (+)
J1-17 (-)

IX (+)
IX (-)

J3-18 (+)
J3-19 (-)

Differential, quadrature, or TTL level encoder
input. The signals are selectable.

For encoder information refer to “Quadrature
Interface Specifications” on page 6-20 and

Figure 6.23, 6.24, 6.25, 6.26, 6.27, 6.28 and
6.29.

J1-18 (+)
J1-19 (-)

ENABLE

J3-20

Enables and disables the drive.

Refer to “Digital Input Specifications” on
page 6-6 a
nd Figure 6.1.

J1-20

FAULT RESET

J3-21

General purpose input, selectable to one of

several drive functions.

Refer to “Digital Input Specifications” on
page 6-6 a
nd Figure 6.1.

J1-21

COMMAND (+)
COMMAND (-)

J3-22 (+)
J3-23 (-)

Analog command signal is a differential type
signal that drives the servo controller.

Separate scale and offset parameters are
used for the input, depending on whether the
signal is a position, velocity or torque com-
mand.

Refer to “Analog Command Input” on
page 6-15 and Figure 6.18.

J1-22 (+)
J1-23 (-)

READY (+)
READY (-)

J3-24 (+)
J3-25 (-)

Contact closure indicates the drive is ready
to follow commands.

Refer to “READY Output Specifications” on
page 6-9 a
nd Figure 6.8.

J1-24 (+)
J1-25 (-)

Table 6.23:

J3 – Auxiliary Connector Pin-Outs

(continued)

Motor Encoder

Pin Number

Description

Internal

Connections

Advertising