Application and Configuration Examples

8-25

16. Choose

Close

to exit the Drive Parameters window.

17. Select the

I/O

C

onfiguration

command icon from the Drive Win-

dow.

18. Select an appropriate digital input from the pull-down lists avail-

able as Digital Input Assignments in the I/O Configuration win-
dow.
For example:

Follower Enable

as Input 1

Not Assigned

as Inputs 2 through 4.

Not Assigned

as Outputs 1 through 4.

19. Choose

Close

to exit the I/O Configuration window.

Tuning

1. Choose the

Tuning

command icon from the Drive window.

2. Select

A

utoTune

from the Tuning mode group.

3. Select the appropriate values for the following Auto Tune com-

mands:

Distance

and

Step Current

.

4. Select the appropriate entry for the Motor Direction:

BiDirectional

,

Forward Only

or

Reverse Only

.

5. Close the toggle switch between J1-26 and J1-20 to enable the

drive.

6. Choose

S

tart

from the Tuning window. The drive powers the

motor shaft for a short period and then motion will cease. Then
ULTRA Master displays the calculated gains and disables the
drive.

7. Choose

N

ormal Drive Operation

from the Tuning window.

Note: Do not attempt to Auto Tune systems that have gravitational
effects. The ULTRA 200 Series will not hold initial position.

!

Intro

ATTENTION: Rotating motor shafts can cause extensive
damage and injury. Motors must be properly guarded dur-
ing testing and installation.